Soigneur FHIR Implementation Guide
0.1.0 - ci-build
Soigneur FHIR Implementation Guide - Local Development build (v0.1.0) built by the FHIR (HL7® FHIR® Standard) Build Tools. See the Directory of published versions
| Active as of 2026-09-08 |
{
"resourceType" : "CodeSystem",
"id" : "cc-load-source",
"text" : {
"status" : "generated",
"div" : "<div xmlns=\"http://www.w3.org/1999/xhtml\"><p class=\"res-header-id\"><b>Generated Narrative: CodeSystem cc-load-source</b></p><a name=\"cc-load-source\"> </a><a name=\"hccc-load-source\"> </a><p>This case-sensitive code system <code>https://fhir.soigneur.coach/fhir/CodeSystem/cc-load-source</code> defines the following codes:</p><table class=\"codes\"><tr><td style=\"white-space:nowrap\"><b>Code</b></td><td><b>Display</b></td><td><b>Definition</b></td></tr><tr><td style=\"white-space:nowrap\">power<a name=\"cc-load-source-power\"> </a></td><td>Power-measured</td><td>Load computed from the ride's power stream (Weighted Power / Intensity / FTP).</td></tr><tr><td style=\"white-space:nowrap\">hr-model<a name=\"cc-load-source-hr-model\"> </a></td><td>HR-estimated</td><td>Load estimated from the ride's HR stream via the per-athlete power↔HR model (15 3.3).</td></tr><tr><td style=\"white-space:nowrap\">hr<a name=\"cc-load-source-hr\"> </a></td><td>HR load</td><td>Load computed from the ride's HR stream via per-sample TRIMP over heart-rate reserve (ADR 0090).</td></tr></table></div>"
},
"url" : "https://fhir.soigneur.coach/fhir/CodeSystem/cc-load-source",
"version" : "0.1.0",
"name" : "CcLoadSource",
"title" : "Soigneur Load-source Codes",
"status" : "active",
"experimental" : false,
"date" : "2026-09-08T13:20:35+00:00",
"publisher" : "Soigneur",
"contact" : [
{
"name" : "Soigneur",
"telecom" : [
{
"system" : "url",
"value" : "https://soigneur.coach"
}
]
}
],
"description" : "How a per-activity Load (`tss`) value was derived: measured from a power stream, estimated from the per-athlete power↔HR model, or computed from the HR stream via heart-rate-reserve TRIMP (ADR 0067 / 0090).",
"jurisdiction" : [
{
"coding" : [
{
"system" : "urn:iso:std:iso:3166",
"code" : "DE",
"display" : "Germany"
}
]
}
],
"copyright" : "Copyright (c) Soigneur. Licensed under CC0-1.0 (public domain dedication). FHIR(R) is the registered trademark of HL7 and is used with permission.",
"caseSensitive" : true,
"content" : "complete",
"count" : 3,
"concept" : [
{
"code" : "power",
"display" : "Power-measured",
"definition" : "Load computed from the ride's power stream (Weighted Power / Intensity / FTP)."
},
{
"code" : "hr-model",
"display" : "HR-estimated",
"definition" : "Load estimated from the ride's HR stream via the per-athlete power↔HR model (15 3.3)."
},
{
"code" : "hr",
"display" : "HR load",
"definition" : "Load computed from the ride's HR stream via per-sample TRIMP over heart-rate reserve (ADR 0090)."
}
]
}